David Vierra 06636fd149 Fix efficiency penalty incorrectly applied to large gas+plasma turbines
This is a copy-paste error from the original code in the large steam
turbine. `aOptFlow` is the optimal flow rate expressed in EU/t, while
`totalFlow` is expressed in fuel L/t
2016-12-08 22:05:59 +01:00
..