Plasma turbine fixes

* Math fixes (no more crazy output numbers)
* getAverage() references removed 
* multiple input hatch support (first fluid-type handled only in case user tries to fuel with different-valued plasma types simultaneously)
* 125% maximum overflow inefficiency
This commit is contained in:
pyure 2015-08-12 15:15:45 -04:00
parent 27da7acbb3
commit 0c7b825e7e

View file

@ -68,22 +68,50 @@ public class GT_MetaTileEntity_LargeTurbine_Plasma extends GT_MetaTileEntity_Lar
return 0;
}
@Override
int fluidIntoPower(ArrayList<FluidStack> aFluids, int aOptFlow, int aBaseEff) {
int tEU=0;
int tOut=0;
int tOptFlow = aOptFlow * 40;
boolean b = false;
for(int i=0;i<aFluids.size();i++){
int fuelValue = getFuelValue(aFluids.get(i));
if(fuelValue>0&&depleteInput(new FluidStack(aFluids.get(i),Math.max(tOptFlow/(fuelValue*2),1)))){
tEU += tOptFlow/2;}
}
if(tEU>0)b=true;
tEU = getAverage(tEU);
if(b&&tEU<=0)tEU=3;
return tEU * aBaseEff / 10000;
}
@Override
int fluidIntoPower(ArrayList<FluidStack> aFluids, int aOptFlow, int aBaseEff) {
aOptFlow *= 40;
int tEU = 0;
int actualOptimalFlow = 0;
if (aFluids.size() >= 1) {
FluidStack firstFuelType = new FluidStack(aFluids.get(0), 0); // Identify a SINGLE type of fluid to process. Doesn't matter which one. Ignore the rest!
int fuelValue = getFuelValue(firstFuelType);
actualOptimalFlow = (int) (aOptFlow / fuelValue);
int remainingFlow = (int) (actualOptimalFlow * 1.25f); // Allowed to use up to 125% of optimal flow. Variable required outside of loop for multi-hatch scenarios.
int flow = 0;
int totalFlow = 0;
for (int i = 0; i < aFluids.size(); i++) {
if (aFluids.get(i).isFluidEqual(firstFuelType)) {
flow = aFluids.get(i).amount; // Get all (steam) in hatch
flow = Math.min(flow, Math.min(remainingFlow, (int) (actualOptimalFlow * 1.25f))); // try to use up to 125% of optimal flow w/o exceeding remainingFlow
depleteInput(new FluidStack(aFluids.get(i), flow)); // deplete that amount
remainingFlow -= flow; // track amount we're allowed to continue depleting from hatches
totalFlow += flow; // track total input used
}
}
tEU = (int) (Math.min((float) actualOptimalFlow, totalFlow) * fuelValue);
if (totalFlow != actualOptimalFlow) {
float efficiency = 1.0f - Math.abs(((totalFlow - (float) actualOptimalFlow) / actualOptimalFlow));
if (efficiency < 0)
efficiency = 0; // Can happen with really ludicrously poor inefficiency.
tEU *= efficiency;
tEU = Math.max(1, tEU * aBaseEff / 10000);
} else {
tEU = tEU * aBaseEff / 10000;
}
return tEU;
}
return 0;
}
}